ZDT Series Automatic Recycle Valve
(ARC valve) is a kind of pump protection device. It automatic protect centrifugal pump when pump body occur cavitation damage or unstable (especially conveying hot water at low load operation medium). Once pump flow is lower than the preseted flow, bypass can completely open to ensure the minimum required flow pump. Even running fully closed, namely running flow is zero, the minimum flow can also pass bypass for Automatic Recycle. Pressure reduced through the multistage bypass pressure reducing valve.
ZDT series automatic recirculation valve has big bypass, and this valve is suitable for bypass with big flow, maximum pressure differential is 4MPa, specific choice is determined by factory.
Introduction
ZDT series automatic recirculation valve (ARC valve) is a kind of pump protection device. It automatic protect centrifugal pump when pump body occur cavitation damage or unstable (especially conveying hot water at low load operation medium). Once pump flow is lower than the preseted flow, bypass can completely open to ensure the minimum required flow pump. Even running fully closed, namely running flow is zero, the minimum flow can also pass bypass for Automatic Recycle. Pressure reduced through the multistage bypass pressure reducing valve.
ZDT series automatic recirculation valve has big bypass, and this valve is suitable for bypass with big flow, maximum pressure differential is 4MPa, specific choice is determined by factory.
Characteristics
- Simple structure, operation reliable and stabile, with few movement parts.
- Be easy for installation, can be installed vertically or horizontally on pump pressure outlet.
- Bypass flow is large, maximum flow is 60% of main flow, KV value can be adjusted.
- Maximum bypass operating pressure differential is 4MPa. Bypass non-return function is optional.
- Applicable medium including: water, oil, methanol and other liquid medium.
Working temperature is from -196℃ to +300 ℃.
Diameter and pressure range
- Valve body type: three-way casting valve
- Nominal diameter: DN25, 32, 40, 50, 65, 80, 100, 200, 250, 300, 350, 400
- Nominal pressure: PN 16, 25, 40, 64, Class 150, 300 L, etc.
- Connection type: flange FF, RF, RTJ, BW, SW etc .
Material temperature range
Body material Sealing material |
WCB | LCB/LCC | CF8 | CF8M |
---|---|---|---|---|
NBR | -20~+100 | -30~+100 | -30~+100 | -30~+100 |
FKM | -20~+200 | -40~+200 | -40~+200 | -40~+200 |
PTFE | -20~+230 | -40~+230 | -80~+230 | -80~+230 |
SS winding gasket | -20~+300 | -40~+300 | -196~+300 | -196~+300 |
Model NO.
ZD | T | Nominal pressure | Body material | Main diameter |
/Bypass diameter | Structure type |
---|---|---|---|---|---|---|
Auto recirculation pump protection valve |
T type bypass assembly |
PN16=PN16 CLSS150 LB=CL150 |
C=WCB LC=LCB P=CF8 PL=CF3 R=CF8M RL=CF3M D=Customed |
DN25=25 NPS1”=1” |
DN25=25 NPS1”=1” |
V=vertically mounted H=Horizontally mounted Z=Bypass non-return D=With discharge mouth |
Such as: T type automatic recirculation valve, pressure is PN40, body material is WCB, main diameter DN50, Bypass diameter DN 25, vertically mounted, Model: ZDT-PN40-C-50/25-V |
Working principle
According to the difference of inductive main flow, main valve disc check cone of automatic recirculation valve will automatically move to a certain position. At the same time the main valve disc drive bypass valve stem, transfer the movement of main valve disc to bypass, through control bypass valve disc position, change bypass throttling area, so as to control bypass flow. When main valve disc back into valve seat closed, all flow backflow through bypass. When mian valve disc to rise to top position, bypass is fully closed, all the flow of pump flow to process system. This valve set four functions in one body.
- Flow perception: automatic recirculation valve main valve disc can automatically perceive main flow of process system, thereby according to the flow to determine position of mian valve disc and bypass disc.
- Recirculation control: automatic recirculation valve can inhaled pump normal operation required minimum flow into storage device through bypass, so as to adjust pump H – Q characteristics, to realize recycling.
- Bypass multistage pressure reducing: bypass control system can reduced the backflow medium from high-pressure pump outlet to appropriate backflow to low-pressure storage device with low noise and small wear.
- Check: automatic recirculation valve also has check valve effect, preventing the liquid backflow to pump body. Bypass non-return function is optional.
- Special bypass size can be customized. The max flow rate of bypass is subject to the max Kv value.
Size
Valve size | mm | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
in | 1 | 11/4 | 11/2 | 2 | 21/2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | |
Max main flow | m3/h | 12 | 28 | 30 | 50 | 100 | 114 | 200 | 400 | 455 | 750 | 1250 | 1650 |
Bypass size | mm | 15 | 20 | 20 | 25 | 40 | 40 | 50 | 80 | 80 | 100 | 100 | 150 |
in | 1/2 | 3/4 | 3/4 | 1 | 11/2 | 11/2 | 2 | 3 | 3 | 4 | 4 | 6 | |
Max bypass Kv | Cv | 2.3 | 4.6 | 4.6 | 6.9 | 18.5 | 18.5 | 34.7 | 69.3 | 69.3 | 116 | 116 | 170 |
Note: Valve mian ouelet size depends on the outlet size of pump.
Parts and material
NO | Name | Material | NO | Name | Material | ||
---|---|---|---|---|---|---|---|
1 | Body | WCB | CF8 | 11 | O ring | EPDM | EPDM |
2 | Recycle disc | 2Cr13 | 304 | 12 | Stud bolt | 45 | 0Cr18Ni9 |
3 | Recycle seat | 2Cr13 | 304 | 13 | Hex nut | 35 | 0Cr18Ni9 |
4 | Screw gland | 2Cr13 | 304 | 14 | Bonnet | WCB | CF8 |
5 | O ring | EPDM | EPDM | 15 | Guide block | 2Cr13 | 304 |
6 | Main disc | 2Cr13+STL | 304+STL | 16 | Bushing | 2Cr13 | 304 |
7 | O ring | EPDM | EPDM | 17 | Porous set | 2Cr13 | 304 |
8 | Gasket | 2Cr13 | 304 | 18 | End ring | 2Cr13 | 304 |
9 | Hexagon nut | 304 | 304 | 19 | Spring 2 | 60Si2Mn | 1Cr18Ni9Ti |
10 | Spring | 60Si2Mn | 1Cr18Ni9Ti |
Dimension and weight
Valve specification DNP DNR |
Size mm(in) | Bypass | Weight Kg | |||
---|---|---|---|---|---|---|
PN10/16/25 150lbs |
PN40/64 300lbs |
|||||
S | H | L | (DNB) | |||
25( 1″) | 115 | 102 | 267 | 15 | 12 | 18 |
32( 11/4″) | 115 | 102 | 267 | 20 | 14 | 20 |
40( 11/2″) | 115 | 102 | 267 | 20 | 14 | 20 |
50( 2″) | 130 | 108 | 305 | 25 | 22 | 26 |
65( 21/2″) | 165 | 127 | 381 | 40 | 46 | 51 |
80( 3″) | 181 | 127 | 381 | 40 | 46 | 51 |
100( 4″) | 209 | 159 | 495 | 50 | 105 | 118 |
125( 5″) | 267 | 220 | 575 | 80 | 143 | 156 |
150( 6″) | 267 | 220 | 575 | 80 | 220 | 240 |
200( 8″) | 300 | 220 | 600 | 100 | 255 | 302 |
250( 10″) | 356 | 305 | 780 | 100 | 400 | 455 |
300( 12″) | 530 | 280 | 830 | 150 | 590 | 650 |
※ Since product innovation and technical innovation or some special requirements, various valve connecting size may change, please contact Datian Valve technical department to get the latest product information.
The following is our product catalogue, company profile, qualification certificates and other related documents
-
ZDT series automatic recirculation valve has big bypass, and this valve is suitable for bypass with big flow, maximum pressure differential is 4MPa, specific choice is determined by factory.pdf 1.87 MB
-
Modern industrial equipment process request centrifugal pump are basically work under condition of variable flow. An automatic recirculation valve (ARC valve) is a multifunctional valve whose primary purpose is to ensure that a pre-determined minimum flow is assured through a centrifugal pump at all times. This is important as centrifugal pumps suffer from overheating and cavitation and can be permanently damaged if they run dry. Through many years of research and development, continuous innovation and practice, shanghai datian valve Co. research ZD series Automatic recirculation control Valve, to prevent overheating, serious noise, unstable and erosion damage of centrifugal pump under low load operation. As long as the flow rate of the pump valve below a certain value, the bypass backflow mouth will automatically open to ensure necessary minimum flow of pump.pdf 4.99 MB