3810/3410 Electric Actuator

What is a 3810/3410 Electric Actuator?

3810, 3410 series electronic type electric actuator, using 220V AC single-phase power as drive power, that is a safety electric actuator accepting computer controller or operator 4-20mADC or 1-5VDC input signal to operate. Its inside has a servo system, no need spare servo amplifier. Key part “ controller “ adopt advanced hybrid integrated circuit, and use resin to solid-cast. After ageing treatment, moistureproof , shockproof. Positioner adjust zero , trip , sensitivity conveniently. Function switch can choose direct action, reaction, choice stop signal three situation. Meanwhile, the actuator has overload protection, temperature protection and compressed spring protecting valve close completely. It is a highly reliable product, with a straight trip and angle trip consist of the electric control valve.

3810/3410 Electric Actuator
3810/3410 Electric Actuator

Technology Parameter

 Parameter name3810 series3410 series
Control
structure
Input signal4~20mADC or 1~5VDC220VAC Switch signal
Opening signal4~20mADC ( load resistor below 500Ω)Feedback 4~20mADC or 0~1.0KΩ
Dead zone0.8~1.0% Can be adjusted to 0.4% 
Zero adjustment25% 
Span adjustment20~100% 
Intrinsic error, Hysteresis1.0% 
Limit control, switchOpen side, close sideOpen side, close side
Opening testPrecision conductive plastic positionerPrecision conductive plastic positioner
PowerPowerAC220±10%    50Hz (AC380V)AC220±10%    50Hz
Drive motorAC reversible single-phase gear motorAC reversible single-phase gear motor
KWA type50 VA50 VA
B type150 VA150 VA
C type220 VA220 VA
D type350VA350VA
AffiliationOverload protection unitA、B type optional, C、D type necessary 
Torque switchThe angular trip can be installed (optional )The angular trip can be installed (optional)
Space heaterOptional, but Exd are not installedOptional ,but Exd are not installed
Hand gearPortable hand crankPortable hand crank
Installation conditionWorking tempNormal without a heater -10℃~+60℃Normal without a heater -10℃~+60℃
Normal with heater -35℃~+60℃Normal with heater -35℃~+60℃
Exd type: -10℃~+60℃Exd type:10℃~+60℃
Allowance vibrationBelow 1.5GBelow 1.5G
Relative humidityNormal:below 95% , Exd type :45~85%Normal:below 95% , Exd type :45~85%
Working gasNo corrosive gasNo corrosive gas
SeamsNormal A、B、C type: 2-PF1/2Normal A、B、C type: 2-PF1/2
Normal D type and Exd type 2-PF3/4Normal D type and Exd type 2-PF3/4
Wiring mouthSignal wire shielding and power wire isolation 
Protection classIP55IP55
Exd classIDX  II   BT4IDX  II   BT4
Note: AC380V needs to point when placing order.

Code

381Action typeModel nameYork nameOutput force
381: adjustment
341: on-off type
L: a straight trip
S: Angular trip
S:Normal type
X:Exd type
A:A Series york
B:B series York
C: C series York
L series push force=*100N
R series torque=*10NM
For example Straight trip adjustment normal type, B series york, push force 5000N: 381LSB-50
Angular trip on-off Exd type, B series york, torque 200NM: 341RXB-20